Home › Failure Case Library › False Positive Amplification from Contamination
PCR (Invitrogen Guide) critical

False Positive Amplification from Contamination

Symptom
PCR products appear in negative control reactions without template. Products may appear in samples expected to be negative.
Common Causes
  1. 1 Primers containing complementary sequences causing self-oligomerization and amplification
  2. 2 Crossover contamination of DNA in work environment
  3. 3 Carryover contamination from previous PCR products
  4. 4 Non-dedicated pipettes or work areas spreading amplicons
Solutions
  1. 1 Redesign primers avoiding complementary and self-complementary sequences that favor primer-dimer formation
  2. 2 Follow general PCR setup recommendations; dedicate separate work area and decontaminate after each use
  3. 3 Use pipette tips with aerosol barriers for all pipetting steps
  4. 4 Implement dUTP incorporation with UDG treatment for carryover control
  5. 5 Maintain separate pre-PCR and post-PCR areas with dedicated equipment
Related Video (3)
Addgene ★ 85
How to Design Primers for PCR
"Directly addresses primer design principles, including avoiding self-complementarity and primer-dimer artifacts that cause false-positive amplification."
YouTube (Curated Tutorials) ★ 82
Primer Design: Important Considerations and Tips for Good Primer Design
"Covers important primer design considerations and tips, helping researchers avoid self-oligomerization and contamination-driven false positives."
Addgene ★ 60
Polymerase Chain Reaction (PCR) Protocol
"Walks through the PCR protocol including negative controls, giving context for spotting false-positive amplification in no-template controls."
Source: thermofisher.com ↗