Transfection critical

Almost no fluorescence signal — transfection essentially failed

Symptom
Under the fluorescence microscope, no GFP signal is visible; Western blot also shows essentially no target protein expression.
Common Causes
  1. 1 Plasmid quality is poor or partially degraded
  2. 2 Transfection reagent has lost activity or dose is wrong
  3. 3 Cells are in poor state (too dense, too sparse, or unhealthy)
  4. 4 Medium contains serum when the reagent requires serum-free transfection step
  5. 5 Protocol step was missed (e.g. complex not mixed adequately)
Solutions
  1. 1 Use high-purity plasmid (OD260/280 ≈ 1.8 – 2.0); avoid old preps
  2. 2 Optimize reagent and DNA amount ratio; check expiry
  3. 3 Use cells in log-phase growth at 70 – 80 % confluence
  4. 4 Use serum-free medium during the transfection step (follow reagent manual)
  5. 5 Strictly follow the protocol; mix the DNA-reagent complex thoroughly before adding
Related Video (3)
Bilibili (China-Accessible Mirrors) ★ 82
Plasmid Transfection in 293T Cells: Principles and Hands-on Protocol
"Plasmid transfection in 293T cells with hands-on protocol provides full procedural context for diagnosing why plasmid transfection gave no GFP signal."
Bilibili (China-Accessible Mirrors) ★ 78
Cell Transfection Operation: Common Mistakes Avoided
"Covers common pitfalls and troubleshooting in transfection, directly relevant to identifying plasmid quality and procedural causes of failure."
YouTube (Curated Tutorials) ★ 72
Plasmid DNA Transfection Protocol
"Plasmid DNA transfection protocol using Lipofectamine LTX specifics reagents and steps that could expose plasmid handling or quality issues."
Source: xiaohongshu.com ↗
← Back to all cases