Home Failure Case Library Massive cell death after transfection — reagent toxicity is too high
Transfection critical

Massive cell death after transfection — reagent toxicity is too high

Symptom
Cells become rounded and detached after transfection; CCK-8 shows a sharp drop in viability vs. mock-transfected control.
Common Causes
  1. 1 Transfection reagent dose is too high or inherently toxic
  2. 2 Cell line is particularly sensitive to this reagent
  3. 3 Complex incubation time on cells was too long
  4. 4 Old medium not replaced after the transfection step
Solutions
  1. 1 Lower reagent dose, or switch to a lower-toxicity reagent (e.g. Lipofectamine 3000 → 2000, or PEI alternatives)
  2. 2 Shorten the complex incubation time on cells (10 – 20 min for fast protocols)
  3. 3 Replace with fresh medium 6 – 8 h post-transfection
  4. 4 For PEI, try different molecular weights (25 kDa vs 40 kDa) or different reagents entirely