Home›Cell Biology›Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
Cell BiologyJoVE (Open Access)Citable · DOI
Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
DOI: 10.3791/51881-v
What you'll learn
✓Prepare surgical field and catheters for vascular implantation
✓Implant carotid artery and jugular vein catheters in rats
✓Connect conscious rat to hemodynamic monitoring system
✓Perform blood sampling, infusions, and pressure measurements
Protocol
Biopharma Insights Vascular accesses to measure hemodynamics, provide fluids and perform blood sampling are important to any small animal model study. We present a technique for implanting catheters into the carotid artery and the common jugular vein in an anesthetized rat for connecting to a system to perform monitoring, infusions and sampling.
Difficulty
advanced
Total time
~3-4 hrs/surgery plus recovery and monitoring
Model organism
Rat
Biosafety
BSL-1
Steps
1
Prepare surgical field and catheters
Sterilize instruments, flush and fill catheters, and prepare the anesthetized rat for aseptic vascular surgery.
▶ 01:12
2
Implant carotid and jugular catheters
Surgically isolate the carotid artery and common jugular vein and insert catheters for vascular access.
▶ 02:17
3
Connect rat to hemodynamic system
Attach exteriorized catheters to the monitoring and infusion system while the rat is conscious.
▶ 06:02
4
Sample blood, monitor pressure, administer drugs
Use the catheters to draw blood samples, record vascular pressures, and deliver test compounds.
▶ 07:25
5
Record vascular pressure measurements
Acquire and interpret hemodynamic pressure readings from the arterial catheter.
▶ 08:06
💬 Comments coming soon
New protocols and pitfalls, in your inbox
A short email when we add notable lab videos and failure cases. No spam, unsubscribe anytime.