Home › Immunology › Complete IHC Immunohistochemistry Protocol for Beginners
Immunology Bilibili (China-Accessible Mirrors)

Complete IHC Immunohistochemistry Protocol for Beginners

🚨 Failure Case Library (10) + Submit your own case

critical
Mouse-on-Mouse Cross-Reactivity in Tissue Staining
High background when using mouse primary antibodies on mouse tissue, caused by secondary antibody binding to endogenous mouse immunoglobulins and Fc receptors rather than only the primary antibody.
💡 4 · ✓ 4
severe
High Background from Insufficient Non-Specific Blocking
Diffuse background staining observed throughout tissue sections in IHC experiments, indicating inadequate blocking of non-specific antibody binding sites.
💡 4 · ✓ 4
severe
Over-Amplified Signal with Biotin-Based Detection Systems
Excessive background staining when using amplification techniques or biotin-based detection, either from high signal amplification or endogenous biotin binding to streptavidin/avidin.
💡 4 · ✓ 4
severe
Incorrect Antibody Diluent Selection
Suboptimal signal intensity or background issues despite correct antibody concentration. Different antibodies show dramatically different performance in TBST/5% NGS versus SignalStain Antibody Diluent.
💡 3 · ✓ 3
severe
Residual Reagent Background from Inadequate Washing
Elevated background signal caused by residual fixative or unbound antibodies remaining on tissue sections between procedural steps, producing false-positive staining.
💡 5 · ✓ 5
severe
Weak or Suboptimal IHC Staining Intensity
Staining signal is present but significantly weaker than expected, with poor contrast between positive cells and background, making interpretation difficult.
💡 5 · ✓ 5
moderate
Non-Specific Binding from Elevated Incubation Temperature
Increased background staining when primary antibody incubation is performed at room temperature, as higher temperatures promote non-specific antibody-tissue interactions.
💡 4 · ✓ 4
moderate
Edge Artifacts from Tissue Section Drying
Higher background staining concentrated at the edges of tissue sections compared to the center, indicating tissue dehydration during the staining procedure.
💡 4 · ✓ 5
moderate
Inadequate Washing Steps Causing Poor Contrast
High background persists with poor contrast between positive signal and background despite other optimization steps, making interpretation difficult.
💡 4 · ✓ 4
moderate
Edge effect / uneven staining across the slide
Slide edges show darker staining than center, or one half stains more than the other; reproducibility between fields is poor.
💡 4 · ✓ 4
💬 Comments coming soon